Yantai Rongfan Electronic Technology Co., Ltd

Yantai Rongfan Electronic Technology Co., Ltd

Manufacturer from China
Verified Supplier
1 Years
Home / Products / PPTC Resettable Fuse /

RF30-060 Pptc Fuse 30V 0.60A Polymer

Contact Now
Yantai Rongfan Electronic Technology Co., Ltd
Visit Website
City:yantai
Country/Region:china
Contact Person:Mssunny
Contact Now

RF30-060 Pptc Fuse 30V 0.60A Polymer

Ask Latest Price
Video Channel
Brand Name :RF
Model Number :RF30-185
Certification :UL/ROHS
Place of Origin :China
MOQ :1000pcs
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :1kk/m
Delivery Time :5-8 work days
Packaging Details :1000/bag
Rated Voltage Dc :30VDC
Application :Wide variety of electronic equipment
Maximum Current :100A
Temperature Coefficient :PTC
I Trip :1.2A
Max Voltage :30V
Color :Yellow
Rohs Compliant :Yes
Type :Polymer Positive Temperature Coefficient Fuse
Operating Voltage Range :6V - 30V
Operating Temp :-40℃---+85℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Positive Temperature Coefficient (PTC) Data Sheet

RF30-060

RF30-060 Pptc Fuse  30V 0.60A  Polymer

Product Dimensions (mm)

A B C D E
Min Max Min Max Min Max Min Max Min Max
- 7.4 - 12.7 4.5 5.5 7.6 - - 3.0

PERFORMANCE RANTINGS

IH IT Vmax I max PD TYP Maximum Time to Trip Resistance(Ω)
(A) (A) (Vdc) (A) (W) Current(A) Time(Sec) Rmin Rmax R1max
0.60 1.2 30 40 0.5 2.5 3.8 0.16 0.20 0.30

IH: Hold current: maximum current device will pass without interruption in 20℃ still air unless otherwise specified .

IT: Trip current: minimum current at which the device will be tripping in 20℃ .

IMAX: Maximum current device can withstand without damage at rated voltage.

Vmax: Maximum voltage device can withstand without damage at rated current.

Pd: Typical Power dissipation: Typical amount of dissipated by the device when in state air environment.

RMIN: Minimum resistance of device as 20℃ prior to tripping..

RMAX: Maximum resistance of device at 20℃ prior to tripping..

R1max:The maximum resistance of the device at 20℃ 1 hour after being tripped.

Thermal Derating Chart-IH(A)

Part NO Maximum ambient operating temperatures()
RF30-060 -40 -20 0 20 25 40 50 60 70 85
0.87 0.79 0.68 0.60 0.58 0.47 0.44 0.42 0.39 0.33

Inquiry Cart 0